Molybdenum wire installation. According to the provisions of molybdenum wire wound toward the wire tube in the reservoir, while the fixed ends. Around the wire, the ends of each wire cylinder reservoir generally remain 10mm, around the middle of nonoverlapping full width of not less than half the length of wire cylinder reservoir to avoid leaving parts motor commutation frequently accelerated damage, but also to prevent frequent participation in cutting molybdenum wire the broken wire.
Machine molybdenum wire cited references have blocked silk rods, wire rod block is made of two rubies guide column, unlike the guide pulley block wire rod rolling motion as to make them directly in contact with the molybdenum wire for sliding friction. So wear out quickly, using molybdenum wire in contact with the cylinder near where it will form a groove, must be checked and make flips and replaced, otherwise there will be folding wire broken wire.